Paper · 2026-07-18 · cs.LG, cs.AI, cs.CV
Investigation of Polycystic Ovary Syndrome (PCOS) Diagnosis Using Machine Learning Approaches
Predicts PCOS from a 541-patient clinical table with five tree-based classifiers (CatBoost, XGBoost, LightGBM, AdaBoost, random forest). Features are picked by RF importance, chi-squared, or label correlation, after random undersampling or oversampling. Author-reported best: AdaBoost with 10 features reaches 94.44% test accuracy under undersampling; CatBoost reaches 94.50% under oversampling.
Feature selectionData resampling for class imbalanceAdaBoostGradient-boosted decision treesmedicaltabularfeature-selectionclass-imbalance
AI-compiled by claude-haiku-5-5 on 2026-11-12, not yet reviewed by a human. Every claim cites its source; check it when a detail matters.
In plain words
Polycystic ovary syndrome is a common hormone condition. Doctors diagnose it from a mix of symptoms, body measurements, hormone blood tests and scans. This paper asks whether a computer model can make the call from a table of those measurements, so a patient could be flagged earlier.
The authors take one public table of patient records. They fill in the gaps with average values and scale every measurement to the same range. Because people with the condition are the smaller group in the table, they also try two ways of balancing the groups. Then they keep only a short list of the most useful measurements, chosen by three different rules, and train five standard prediction models on that list. The best combination gets a little over 94% of the held-out cases right. The paper reports this on one table, with no outside data, so it is a first check and not evidence that the method works in a clinic.
TL;DR
- Five tree-based classifiers predict PCOS from a 43-feature clinical table of 541 patients § II.A.
- Feature subsets of 5, 10 and 15 are chosen by random-forest importance, chi-squared score, or correlation with the label § III tab. I tab. II.
- The headline is AdaBoost with 10 features at 94.44% test accuracy under undersampling tab. I. CatBoost reaches 94.50% under oversampling tab. II.
- No hyperparameters, seeds, run counts or variance are reported, and there is no baseline with all features. Treat the numbers as a single-split, author-reported result.
Problem
Early PCOS diagnosis usually combines history, examination and lab tests § I. The authors argue that a data-driven model could help with earlier screening, and that the field has had less work on clinical tabular data than on image-based PCOS detection § I. The paper assumes that the 43 recorded features contain redundant or noisy columns, and that a small, well-chosen subset gives better test accuracy § III § IV.A.
The dataset is imbalanced: fig. 2 shows roughly twice as many non-PCOS as PCOS rows. Read by eye from the bar chart, the counts are about 360 and 180; the exact counts are not stated in the text fig. 2 § II.A.
Method
Data. A public PCOS table from ten medical facilities in Kerala, India, with 541 patients, 43 features and one binary label (1 = PCOS, 0 = no PCOS). It is cited as a Kaggle dataset (“PCOS diagnosis” by karnikakapoor), reference [14] § II.A.
Preprocessing, in the order the paper describes it.
- Missing numeric values are replaced with the mean of their column § II.B.
- Each feature is min-max scaled to [0, 1] § II.C.
- Class balance is changed by random undersampling (drop majority rows until balanced) or random oversampling (copy minority rows). SMOTE is described as well § II.D. The results use undersampling in § IV.A and random replication in § IV.B. Whether SMOTE was used for any reported number is not stated.
- The table is split 70/30, then the 30 % part is split 50/50, giving a 70 / 15 / 15 train, validation and test split § II.E.
Feature selection. Three selectors are compared, each returning a ranked list from which the top k are kept, with k = 5, 10 or 15 § III tab. I tab. II.
- RF (random forest importance). Impurity-based importance from a random forest, with Gini impurity as the measure. fig. 3 ranks the top 15 features by this score § III.A.
- Ch2 (chi-squared). Chi-squared score between each feature and the label. The text presents it as the choice for categorical features § III.B.
- HC and LC (correlation). Each feature is scored by its correlation with the label. High correlation (HC) keeps the strongest; low correlation (LC) keeps the weakest. The text describes the measure as linear, but does not name the coefficient § III.C.
Classifiers. CatBoost, XGBoost, LightGBM (LGBM), AdaBoost and random forest (RF), each trained on the selected features § II.F. The section describes each method in general terms. It gives no model settings.
Training and evaluation. Models are trained on the training split and scored on the test split § II.G. The paper lists test accuracy as the main metric, with precision, recall, F1, Matthews correlation coefficient and Cohen's kappa also named § II.H. Only test accuracy appears in the results tables tab. I tab. II.
Pipeline, as written. Section order is kept, so sampling comes before the split. The paper does not say whether any step was fitted on training rows only.
# PCOS classification pipeline [§ II] [§ III] [§ IV]
# Input: table (541 rows, 43 features), binary label
# Output: test accuracy for one (model, selector, k, sampling) setting
def run_setting(rows, labels, selector, k, sampling, model_name):
# Replace missing numeric values with the column mean [§ II.B]
rows = fill_missing_with_column_mean(rows)
# Scale each feature to [0, 1] [§ II.C]
# Fit scope (all rows or training rows only): not stated
rows = min_max_scale(rows)
# Balance the classes [§ II.D] [§ IV.A] [§ IV.B]
# Undersampling in IV.A; random replication in IV.B
rows, labels = resample(rows, labels, sampling)
# Split 70 / 15 / 15 (train / validation / test) [§ II.E]
# Validation use: not stated
train, valid, test = split_70_15_15(rows, labels)
# Rank features and keep the top k [§ III]
# Whether the ranking sees the test rows: not stated
keep = top_k_features(train, selector, k)
# Fit one classifier on the kept features [§ II.F]
# Hyperparameters: not stated
model = fit(model_name, train[keep], train.labels)
# Accuracy on the held-out test split [§ II.G] [§ II.H]
return accuracy(model.predict(test[keep]), test.labels)Hyperparameters
| Name | Value | Where | Notes |
|---|---|---|---|
| Missing values | column mean | § II.B | Fit scope not stated |
| Scaling | min-max to [0, 1] | § II.C | Fit scope not stated |
| Undersampling | random removal of majority rows until balanced | § II.D | Target ratio not stated; balanced result per § IV.A |
| Oversampling | random replication of minority rows | § IV.B | SMOTE described in § II.D; not stated whether used |
| Split | 70 / 15 / 15 | § II.E | Derived from two stated 70/30 and 50/50 splits |
| Feature count k | 5, 10, 15 | tab. I tab. II | Only these three values are reported |
| RF importance | Gini impurity | § III.A | Number of trees not stated; text says "typically hundreds" |
| Chi-squared | Ch2 score | § III.B | Applied to continuous features: not stated |
| Correlation | HC and LC, with the label | § III.C | Coefficient and sign convention: not stated |
| Classifier settings (all five) | not stated | § II.F | Text mentions "hyperparameter tuning" with no values or search procedure |
| Random seed | not stated | — | — |
| Number of runs | not stated | — | Each cell in the tables appears to be one value |
| Class weights | not stated | — | — |
Results
Author-reported. Setup: one public table of 541 patients, 43 features and a binary label § II.A. Five classifiers, three selectors and k in {5, 10, 15}, with undersampling in tab. I and random oversampling in tab. II. Test accuracy in percent. Hardware and baseline: not stated. The paper reports no run with all 43 features.
Headline numbers, each as the paper states them:
- Undersampling: AdaBoost, k = 10, RF or HC: 94.44% tab. I § IV.A.
- Oversampling: CatBoost, k = 15, HC: 94.50% tab. II § IV.B.
- The abstract and conclusion name AdaBoost with RF and HC at k = 10 as the best result § V. That holds only for tab. I.
Table I. Undersampling, test accuracy (%) tab. I. Headers are shortened here; the values are unchanged.
| Model | k | RF | Ch2 | HC | LC |
|---|---|---|---|---|---|
| CatBoost | 5 | 83.33 | 75.93 | 83.33 | 53.70 |
| CatBoost | 10 | 90.74 | 83.33 | 87.04 | 66.67 |
| CatBoost | 15 | 90.74 | 88.89 | 85.19 | 51.85 |
| XGBoost | 5 | 75.93 | 72.22 | 75.93 | 59.26 |
| XGBoost | 10 | 87.04 | 81.48 | 81.48 | 61.11 |
| XGBoost | 15 | 87.04 | 83.33 | 75.93 | 59.26 |
| LGBM | 5 | 77.78 | 72.22 | 77.78 | 55.56 |
| LGBM | 10 | 88.89 | 83.33 | 85.19 | 59.26 |
| LGBM | 15 | 90.74 | 83.33 | 83.33 | 57.41 |
| AdaBoost | 5 | 90.74 | 74.07 | 90.74 | 53.70 |
| AdaBoost | 10 | 94.44 | 87.04 | 94.44 | 50.00 |
| AdaBoost | 15 | 87.04 | 87.04 | 81.48 | 48.15 |
| RF | 5 | 81.48 | 75.93 | 81.48 | 61.11 |
| RF | 10 | 88.89 | 85.19 | 87.04 | 61.11 |
| RF | 15 | 85.19 | 85.19 | 88.89 | 62.96 |
Table II. Oversampling, test accuracy (%) tab. II. Same headers and values.
| Model | k | RF | Ch2 | HC | LC |
|---|---|---|---|---|---|
| CatBoost | 5 | 87.16 | 81.65 | 87.16 | 74.31 |
| CatBoost | 10 | 93.58 | 92.66 | 90.83 | 77.98 |
| CatBoost | 15 | 91.74 | 91.74 | 94.50 | 78.90 |
| XGBoost | 5 | 86.24 | 82.57 | 86.24 | 63.30 |
| XGBoost | 10 | 91.74 | 88.99 | 89.91 | 77.06 |
| XGBoost | 15 | 89.91 | 90.83 | 91.74 | 77.98 |
| LGBM | 5 | 85.32 | 82.57 | 85.32 | 64.42 |
| LGBM | 10 | 92.66 | 90.83 | 89.91 | 77.06 |
| LGBM | 15 | 90.83 | 93.58 | 91.74 | 79.82 |
| AdaBoost | 5 | 86.24 | 85.32 | 86.24 | 66.06 |
| AdaBoost | 10 | 88.99 | 88.99 | 89.91 | 71.56 |
| AdaBoost | 15 | 89.91 | 92.65 | 91.74 | 66.97 |
| RF | 5 | 88.07 | 81.65 | 88.07 | 65.14 |
| RF | 10 | 90.83 | 88.99 | 91.74 | 74.31 |
| RF | 15 | 93.58 | 92.66 | 91.74 | 75.23 |
No variance, confidence interval or repeated-run result is reported.
Paper vs code
No official code. The paper and arXiv metadata link no repository or project page. GitHub searches for “PCOS feature selection” and “PCOS AdaBoost random forest”, and a user search for the author names, found no repository owned by the authors. Several third-party PCOS repositories exist; none is used here.
Pitfalls
- Order of sampling and split. Sampling is described before the split § II.D § II.E. If implemented that way, copies of minority rows (random oversampling) can appear in both training and test. Split first and resample only the training rows. The paper does not say which it did.
- Fit scope. Mean imputation and min-max scaling are not stated to be fitted on training rows only. Fitting on all rows leaks test statistics.
- Selector fit data. Whether RF importance, chi-squared and correlation were computed on training rows or on all rows is not stated § III.
- Identifier-like columns. fig. 3 ranks “Sl. No” and “Patient File No.” among the top 15 features by RF importance. The text does not say whether these were dropped first. If kept, they carry no clinical meaning and may encode row order.
- Chi-squared scope. The text presents chi-squared as the choice for categorical features § III.B, but the feature list includes continuous measurements fig. 3. The paper does not say how continuous features were scored.
- Correlation definition. HC and LC are not given a formula, coefficient or sign rule § III.C. An implementation must choose one; the card does not guess.
- Test-set size is inferred, not stated. Most values in tab. I are multiples of 1/54 (for example 94.44 = 51/54), and most in tab. II are multiples of 1/109 (for example 94.50 = 103/109). This suggests test sets of about 54 and 109 rows. One value, 92.65 in tab. II, is not a multiple of 1/109 (101/109 = 92.66). Differences between settings are often one to three test rows, and no repeats are reported.
- Accuracy is the only reported metric. The paper names precision, recall, F1, MCC and kappa § II.H but reports none. With about a 2:1 class imbalance fig. 2, accuracy alone can hide poor recall on PCOS cases.
- Headline claim. The abstract says AdaBoost gives the highest test accuracy. That holds only within tab. I (94.44%). tab. II reaches 94.50% (CatBoost, HC, k = 15). Section IV.B also calls 91.74% the highest result “consistently achieved”, but CatBoost reaches 94.50% in the same section § IV.B.
- Feature selection baseline missing. No result uses all 43 features tab. I tab. II, so the gain from selection is not measured against a no-selection baseline. The conclusion says the top 10 features improved performance § V. The best oversampling setting for AdaBoost used 15 features (Ch2, 92.65%) tab. II.
- Validation split unused in the text. A 15 % validation split is created § II.E, but its use is not stated. The text mentions cross-validation and hyperparameter tuning as mitigations § II.F § III, yet gives no procedure or values.
- Classifier settings absent. No hyperparameters are given for any of the five models. Results cannot be reproduced from the paper alone.
- Oversampling method. § IV.B uses random replication, not SMOTE, although § II.D describes SMOTE. The card does not assume SMOTE was used anywhere.
- Single public table, no external validation. All results come from one dataset, with no external cohort and no clinical study.
- Dataset license not stated. The paper cites a Kaggle dataset § II.A and does not state its license. Check it before commercial reuse of any derived data; this card does not establish it.
Lineage
- Builds on: general methods (CatBoost [ref. 19], XGBoost [ref. 20], LightGBM [ref. 21], AdaBoost [ref. 22], random forest [ref. 23]) as cited in the paper § II.F. The card does not restate their claims.
- Compared against: no prior PCOS model is compared. The related-work section lists image-based PCOS methods (stacked ensembles on ultrasound, particle-swarm follicle segmentation, SVM/kNN/neural-network classifiers) § I, but no numbers from them are reported.
- Superseded by: not known from content already in this wiki.
Source and license
Adapted from “Investigation of Polycystic Ovary Syndrome (PCOS) Diagnosis Using Machine Learning Approaches” by Al Zadid Sultan Bin Habib, Md Asif Bin Syed, Md. Ekramul Islam, Tanpia Tasnim (arXiv:2607.16941), used under CC BY 4.0. Changes: condensed and restructured for implementation, with tables, equations and algorithms taken from the paper and its code, each cited to its source. Not affiliated with or endorsed by the authors.