Tendon-driven actuation

Moving a flexible or articulated part by pulling a tendon, cable or backbone from an actuator placed away from the moving part. The actuator can sit outside the instrument, which keeps the instrument small. The trade-off: friction, backlash and stretch in the line make the position and the tip force hard to predict and to sense.

roboticsactuationsurgical-roboticsmedical-robotics

Markdown4 min read

AI-compiled overview, updated 2026-11-12, not yet reviewed by a human. Every claim cites its source; check it when a detail matters.

Overview

In tendon-driven actuation, a line runs from a motor or actuator to the part it moves. It is called a tendon, a wire, a cable or, for a continuum arm, a backbone. Pulling the line bends or moves the part at the far end. The review describes the general reason for this design: the actuators are placed remotely from the end effector, which helps miniaturise the instrument 1807.03731 §3.3. Robots designed for natural orifice and minimally invasive surgery are mostly wire-actuated, with recent growth in continuum robots as the exception 1807.03731 §3.3.

The cost sits in the line itself. The review states that compliance, motion losses and friction in the actuation lines reduce the accuracy of the end effector's motion. They also weaken force sensing and can reduce control stability 1807.03731 §3.3. A model that maps motor angle to tip position is therefore biased, and the bias depends on load and history. The rest of this page covers the design variants the review names, the losses it lists, and the compensation methods it reports.

Variants

Wire-actuated articulated end effector

Serial arms with a jointed wrist are driven by wires that run from the base to the joints. The review cites the da Vinci single-site system and the SAIT-KAIST single-port system as examples. Both use articulated serial structures that rely on wire actuation to control their end effectors [arxiv:1807.03731 §3.1, fig. 4]. The joints give dexterity at the tool tip, but the wires add the friction and stretch described above 1807.03731 §3.3. Card: Medical Technologies and Challenges of Robot Assisted Minimally Invasive Intervention and Diagnostics.

Multi-backbone push-pull continuum arm

A multi-backbone continuum architecture drives several backbones in push-pull pairs. The review gives the IREP robot as an example. It uses push-pull actuation on a number of superelastic NiTi backbones to set the bending shape of each segment 1807.03731 §3.1, fig. 4. Friction and coupling models have been built for multi-backbone robots of this kind 1807.03731 §3.3.

Bowden cable with sheath

The line runs inside a sheath, as in a Bowden cable. The review shows Bowden cable actuation as one case of the drive for these robots [arxiv:1807.03731 §3.3, fig. 6]. Here the friction comes from the sheath, and it depends on how the sheath curves between the actuator and the end effector. The review does not give a rule for choosing between the variants.

Losses and how they are modelled

The review lists several friction models without preferring one 1807.03731 §3.3.

  • A simple transmission model assumes Coulomb friction. A dynamic model adds the viscoelastic properties of the tendon 1807.03731 §3.3.
  • For a Bowden pair, a capstan-type friction loss is approximated by constant radii of curvature along the sheath. Non-uniform curvature is handled with a continuous time-domain model of tendon-sheath transmission [arxiv:1807.03731 §3.3].
  • Conduit-induced friction has been added to the kinematic model of a multi-section tendon robot 1807.03731 §3.3.

The review also reports ways to offset the losses:

  • Recursive linear estimation, using measured actuator positions and the measured end-effector pose, can estimate backlash and correction factors for the elastic properties 1807.03731 §3.3.
  • A Fourier-series characterisation of the motion losses, combined with feed-forward compensation from a statics model, has been used on a multi-segment multi-backbone robot 1807.03731 §3.3.
  • A smooth hyperbolic-tangent inverse has been used as backlash feed-forward compensation in wire-actuated robots. For catheters, a dead-zone model of the backlash, combined with Coulomb friction, has been used [arxiv:1807.03731 §3.3].

If the model is not enough, many works add an external measurement of the tip to the control loop. Examples the review names are image tracking and electromagnetic sensing 1807.03731 §3.2.

When to use which

The review does not rank these options and reports no measured comparison. The table reads its section descriptions against the situation.

SituationUseWhy
The actuators must be kept away from a small moving partTendon or cable drive, with actuators placed remotelyThis is the reason the review gives for remote actuation 1807.03731 §3.3
The tool needs jointed dexterity at its tipWire-actuated articulated end effectorThe review cites this design for single-site and single-port systems 1807.03731 §3.1
The arm must bend along its length through a narrow pathMulti-backbone push-pull armThis is the design the review gives for multi-segment bending 1807.03731 §3.1, fig. 4
The line runs through a sheath with bendsModel the sheath friction, such as with the Bowden or tendon-sheath modelsThe review lists these models for sheath curvature and friction 1807.03731 §3.3
Motor readings alone must give tip positionCompensate backlash and friction in the modelThe review names friction, backlash and stretch as the causes of the error 1807.03731 §3.3
Tip accuracy must be better than the model allowsAdd an external tip measurement to the loopThe review names image tracking and electromagnetic sensing for this 1807.03731 §3.2

The review does not give numeric accuracy for any of these options, so the table does not state how large the gains are.

Implementation sketch

The review gives no code for these methods, and it does not state their parameters. This sketch models backlash as a dead zone, which the review reports for catheters 1807.03731 §3.3. It leaves out friction. The dead-zone width is a free parameter that has to be measured for each line.

Pseudocode
# Backlash as a dead zone on the output of a tendon line
# Input:  commanded displacement u, previous output y_prev,
#         backlash width b (measured per line)
# Output: displacement y transmitted to the end effector
# Convention: the slack is split evenly, b/2 on each side (not from the review)

def transmit(u, y_prev, b):
    # The output moves only once the command leaves the slack band around
    # the previous output  [arxiv:1807.03731 §3.3]
    if u > y_prev + b / 2:
        return u - b / 2
    if u < y_prev - b / 2:
        return u + b / 2
    # Inside the slack: the output stays where it was
    return y_prev

Contradictions

None known. The review lists several friction and backlash models for the same kinds of line, and it does not compare them 1807.03731 §3.3. This is a gap in its coverage, not a disagreement between sources.

Papers

Source and license

Compiled from the papers listed on this page, all published under CC BY, CC BY-SA or CC0, with citations. See each paper's page for its authors and license.