## Overview

The question is how much CO2 one job emits when it runs on rented GPUs. The
shared idea is that emissions equal the energy the job consumes multiplied by
the carbon intensity of the electricity at the time and place it is consumed.
The paper calls the part it measures the operational term, O = E × I, where E
is energy in kWh and I is a location-based marginal intensity in gCO2eq per
kWh [arxiv:2206.05229 §3.1] [arxiv:2206.05229 eq. 2]. Embodied carbon of the
hardware is left out and named as future work [arxiv:2206.05229 §3.1]
[arxiv:2206.05229 §8].

Only one paper in this wiki covers the topic so far, so the variants below
describe that paper's method, its scope choices and the alternative it argues
against. Card: [Measuring the Carbon Intensity of AI in Cloud Instances](/papers/2206.05229).

## Variants

### Measured GPU energy times marginal intensity

Energy is read from the GPU with nvidia-smi during the run. CPU and memory
power are measured too, but the emission estimate counts GPU energy only
[arxiv:2206.05229 §3.2]. Each interval's energy is multiplied by the marginal
intensity for that interval, and the products are summed to give the job's
total [arxiv:2206.05229 §5]. The intensity series is WattTime marginal data at
5-minute resolution [arxiv:2206.05229 §6]. Reported results range from 34 to
128 gCO2eq per GPU-hour and from 200 to 755 gCO2eq per kWh across 16 Azure
regions, averaged over a year [arxiv:2206.05229 §5.1].

### Shifting the job in time or region

The same intensity signal can drive a scheduler. Flexible Start picks the
start time inside a window that gives the lowest total emissions. Pause and
Resume runs the job only in the cleanest intervals of a window
[arxiv:2206.05229 §6]. Both are simulated on historical data with perfect
foresight, and the paper treats the gains as upper bounds on what a real
scheduler could reach [arxiv:2206.05229 §6]. The largest reported gain is
27.7% for DenseNet 121 under Pause and Resume with a 24-hour extension
[arxiv:2206.05229 tab. 4].

### Averaged or post-hoc estimates (argued against)

The paper says earlier estimates often used coarse regional averages or data
that was not public [arxiv:2206.05229 §1]. It argues for the marginal rather
than the average signal, because the marginal signal shows what a change in
demand does to the grid [arxiv:2206.05229 §2] [arxiv:2206.05229 §3.1]. In its
own comparison, it expects prior figures to be higher because they include
data-centre overhead such as PUE, and it finds most prior estimates inside
its own ranges [arxiv:2206.05229 §5.1]. The paper does not run an average-intensity
estimator of its own on these workloads.

## When to use which

| Situation | Use | Why |
|---|---|---|
| Per-job estimate on a cloud GPU you can meter | GPU energy times marginal intensity | This is the paper's method [arxiv:2206.05229 §3.1] [arxiv:2206.05229 §3.2] |
| Full data-centre figure, including CPU, RAM, cooling and PUE | Outside this method | The paper excludes these, so its numbers are lower bounds [arxiv:2206.05229 §3.2] |
| No hourly marginal intensity series for the region | Compare regions only, if at all | Time-based results need a time series [arxiv:2206.05229 §6] |
| Choosing where to run a flexible job | Compare regions first | The paper finds region choice matters most [arxiv:2206.05229 §6.1] [arxiv:2206.05229 tab. 4] |
| Choosing when to run a flexible job | Flexible Start or Pause and Resume, with gains read as upper bounds | Historical data and perfect foresight [arxiv:2206.05229 §6] |
| Expecting a time-of-day effect in one place | Do not assume it | The only time-of-day evidence is one BERT run over three days in one region [arxiv:2206.05229 tab. 3] |

Gains from pausing depend on job length and on the allowed extension. For the
6B model the Pause and Resume gain is 2.5% at a 24-hour extension and 11.4% at
a 100% extension [arxiv:2206.05229 tab. 4] [arxiv:2206.05229 tab. 5].

## Implementation sketch

Operational emissions of one job, from energy and intensity on the same
5-minute grid [arxiv:2206.05229 §3.1] [arxiv:2206.05229 §5]:

```pseudocode
# Operational emissions of one GPU job  [§3.1] [eq. 2] [§5]
# Input:  energy (T,) kWh per 5-min step, GPU only  [§3.2]
#         intensity (T,) gCO2eq per kWh, marginal, same steps  [§6]
# Output: total gCO2eq

def operational_emissions(energy, intensity):
    # Each step: energy used times the marginal intensity of that step  [eq. 2]
    total = 0.0
    for e, i in zip(energy, intensity):
        total += e * i
    # Cumulative emission is the sum over all steps  [§5]
    return total
```

Implementation notes:

- Align the two series before multiplying. The paper's results depend on both
  being on the same 5-minute grid [arxiv:2206.05229 §6].
- Keep units explicit. The paper reports both per GPU-hour and per kWh, and
  its time-of-day table has no units [arxiv:2206.05229 §5.1] [arxiv:2206.05229 tab. 3].
- The paper's scheduling simulations replay the job's measured energy profile
  from its start. Replaying it over non-contiguous paused steps is not
  described in the paper; treat that mapping as your own choice
  [arxiv:2206.05229 §6].

## Contradictions

Within the single paper, several numbers disagree:

- **Finetuning energy.** The text gives 3.2 kWh [arxiv:2206.05229 §4], while
  [arxiv:2206.05229 tab. 2] and the appendix caption [arxiv:2206.05229 fig. 6]
  give 3.1 kWh.
- **Full 6B run.** The text extrapolates (60/8) × 13.8 MWh ≈ 103.5 MWh
  [arxiv:2206.05229 §4]. The caption of [arxiv:2206.05229 tab. 2] gives
  103,593 kWh. The extrapolation assumes linear scaling from a run stopped at
  about 13% of completion, which the paper does not validate.
- **Duration saving.** The caption of [arxiv:2206.05229 fig. 4] says doubling
  the 6B run's duration can save "up to about 25%". The averaged 100% result in
  [arxiv:2206.05229 tab. 5] is 11.4%. The caption does not say whether the 25%
  refers to one region or month.
- **Model size.** The energy measurement run uses BERT-base
  [arxiv:2206.05229 §3.2] [arxiv:2206.05229 tab. 1]. The pretraining and
  finetuning runs are described as BERT-small [arxiv:2206.05229 §4]. The paper
  does not say which model the 37.3 kWh pretraining energy comes from.

No cross-paper disagreements are known yet.